Free on-site gate assessment - hinges, posts, and your LiftMaster or Nice gate operator checked before anything is quoted
The assessment is free and the quote is the invoice.





DoorKing Access Control Installation: The Burleson Owner’s Guide
We install and replace DoorKing access control components across Burleson, and most jobs run between $450 and $1,200 installed, depending on whether you need a keypad, card reader, telephone entry system, or a full board swap. We stock the most common DoorKing-compatible parts on the truck, so the majority of access control replacements in Burleson homes are finished the same day we arrive. The way owners usually find the problem is simple: the keypad stops beeping, the card reader ignores every card in the family, or the gate opens fine from the button in the house but not from the call box at the street.
We’re an independent service provider, not affiliated with DoorKing, which means we carry both OEM DoorKing parts and quality aftermarket equivalents, and we’ll tell you the honest difference before you spend a dollar.
Key Takeaways
- DoorKing access control installation in Burleson typically runs $450-$1,200 installed.
- We stock common DoorKing keypads, readers, and control boards on the truck for same-day repair.
- Your price is quoted and agreed before any work starts - no surprises on the bill.
- Every job is backed by our written 90-Day Done Right Promise.
Which DoorKing Models This Applies To
DoorKing has been making telephone entry and access control systems for decades, and Burleson driveways have a lot of the older 1812 and 1814 telephone entry systems, the 1830-series keypads, and the microPLUS and microCLICK control boards still in service. The compatibility gotcha most owners run into is this: an old 1812 keypad will not talk to a newer microPLUS board without a retrofit adapter, and a DoorKing 8064 card reader that worked for fifteen years may not be recognized by a board someone replaced five years ago. Before you buy any part online, check the label on the inside of your control box for the model and revision number - that little sticker is what we use to match parts correctly the first time.
When it comes to OEM versus aftermarket, the honest answer for DoorKing is this: for keypads and card readers, a quality aftermarket unit from a reputable supplier will usually outlast the warranty period and save you 30 to 40 percent. For control boards and telephone entry modules, we recommend OEM DoorKing parts. The boards have tighter voltage tolerances, and a cheap aftermarket board is a false economy when it fails again during a Texas thunderstorm. We keep both options in mind and will quote you whichever makes sense for your system’s age and how long you plan to stay in the house.
Signs Your DoorKing Access Control Installation Is Failing
- Keypad buttons work intermittently or need a hard press. The membrane on outdoor keypads breaks down over time - Burleson summers bake the plastic, and the contacts underneath gradually lose their snap. The fix is a new keypad face or unit, not a board replacement.
- Gate opens from the house button but not from the call box. This usually points to a failed relay on the access control board or a broken wire running out to the street. Wiring in this part of Texas gets brittle after ten to fifteen years, especially in direct sun.
- Card reader accepts some cards but not others. The reader’s radio frequency drifts as the internal oscillator ages. If your cards are DoorKing’s older 26-bit format, a new reader will usually solve it - but we’ll test the cards before we condemn the reader.
- Telephone entry unit does not ring the house or lets someone in without a code. These have their own surge protection that fails silently, often after a lightning strike nearby. The relay can stick closed, which means anyone can get in - call us the day you notice it.
- Display is blank or shows garbled characters. On the 1814 and 1830 series, this is typically the LCD or its ribbon connection. It’s a twenty-minute fix with the right part on hand, not a reason to buy a whole new entry system.
Replacement Cost & What’s Included
For Burleson homes, here is what DoorKing access control installation realistically costs installed:
- Keypad replacement (single-gang, surface mount): $450-$650 installed
- Card reader add-on or replacement: $475-$700 installed
- Control board replacement (microPLUS or microCLICK): $600-$950 installed
- Full telephone entry replacement (1812/1814 style): $850-$1,200 installed
The range depends on the age of your wiring, how far the call box is from the control box, and whether we need to add a surge protector so the new part doesn’t fail the same way. Every quote includes the part, labor, wiring cleanup where needed, programming of existing codes and cards, and a test of the full open-close cycle. We quote the price before we start and we don’t add line items halfway through. The work is covered by our 90-Day Done Right Promise, in writing.
DIY or Call Us?
An access control board or keypad is low-voltage, so it won’t hurt you the way a gate spring will, but it will frustrate you. What you can safely check: the power supply lights on the control box, whether the keypad beeps when you press a button, and whether the gate opens from the manual button. What goes wrong with DIY is usually this: the owner bought a part online that is not revision-compatible, and now the new keypad doesn’t work and the old one is in the trash, so we’re fixing two problems instead of one. If you’re handy and certain of the part number, this is a job you can do. If you’d rather have it done once, call us at (469) 564-8046 and we’ll match the part, install it, and stand behind it. Victor Salinas will tell you exactly what is wrong before we touch anything.
FAQs
A DoorKing keypad or card reader in Burleson typically lasts 8 to 12 years outdoors, with control boards usually lasting 10 to 15 years. Our Texas heat and occasional lightning storms are what shorten that lifespan, which is why surge protection matters. Call (469) 564-8046 for an exact quote on your system.
Some parts can be repaired - a bad ribbon cable on a display, a corroded wire terminal, or a stuck relay - but keypad membranes and most control board component failures are replace-not-repair jobs. We’ll tell you honestly which category yours falls into before quoting anything. Call (469) 564-8046 and we’ll walk you through it.
Most access control installations in Burleson take 1 to 2 hours on site, including programming your existing codes and cards and testing the full gate cycle. If new wiring to the street is needed, add another hour. We’ll give you an accurate window when we schedule the visit.
We stock the most common DoorKing keypads, card readers, and control boards on our trucks, along with parts for LiftMaster, Mighty Mule, and Ghost Controls systems. If your part is a less common revision, we’ll have it in hand within a few days before we come out. Call (469) 564-8046 with your model number and we’ll check availability right then.
Written by Victor Salinas, Owner, Ironworks Gate Co. at Ironworks Gate Co., serving Burleson and nearby areas.
Before
After
Before
After
Before
After